WEKO3
アイテム
{"_buckets": {"deposit": "f84b13aa-5021-4b23-b263-93e1792c8df0"}, "_deposit": {"created_by": 15, "id": "348", "owners": [15], "pid": {"revision_id": 0, "type": "depid", "value": "348"}, "status": "published"}, "_oai": {"id": "oai:cis.repo.nii.ac.jp:00000348", "sets": ["31"]}, "author_link": ["1065", "784", "1067", "782", "680", "785", "1068", "1063", "786", "683", "1066", "1064"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-03-28", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "14", "bibliographicPageEnd": "69", "bibliographicPageStart": "64", "bibliographic_titles": [{"bibliographic_title": "千葉科学大学紀紀要"}, {"bibliographic_title": "The University Bulletin of Chiba Insitute of Science", "bibliographic_titleLang": "en"}]}]}, "item_10002_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "高性能先端分析( High-performance Frontal Analysis, HPFA)法は HPLCシステムを利用する薬物 血漿タンパク結合分析法であり、オンラインで簡便、高感度な結合分析が可能となる。これまでの検討では、血中モデルタンパク質としてヒト血清アルブミン( HSA)を採用し、本法にて様々な薬物との解析を試みてきた。HSAは 分子量約66500の主要な血漿タンパク質であり、通常35~50g/L≒ 500~750μMの濃度で血漿中に存在しているが、モデル試料においてはHPFA解析モデルの立証と再現性のみに注視し、100μMの濃度で固定して測定を行ってきた。そこで本研究では、試料中HSA総濃度を 変更したときに、薬物-血漿タンパク結合解析から得られる結合定数に変化が見られるかを検討した。オンラインHPFAシステムを構築し、HPFA分離カラムにDevelosil 100Diol-5(6.0 mmI.D.×150mm, Nomura Chemical Co.,Ltd)、薬物定量カラムに5C18-MS-II(2.0mmI.D.×150mm,nacalai tesque,Inc.)を使用、モデル薬物にはphenylbutazone(PB)を 採用し、100、50、10μMのHSA総濃度に対し複数のPB濃度で混合した試料を作成して、カラム温度37℃の条件で測定した。得られた非結合型薬物濃度からLangmuir型のプロットより回帰計算(Kaleida Graph™ ver.4.5, Synergy Software)を行い、結合定数を算出した。HSA総濃度を変化させてもLangmuir型プロットは同一のものとなり、算出した結合定数、及び結合サイト数も同一の値となった。本検討結果より、HPFA解析においてHSA濃度を変化させても影響はなく、薬物 -血漿タンパク結合における評価の妥当性があることが示された。", "subitem_description_type": "Abstract"}]}, "item_10002_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "千葉科学大学"}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "2436-2565", "subitem_source_identifier_type": "ISSN"}]}, "item_10002_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "杉本, 幹治"}, {"creatorName": "スギモト, カンジ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "782", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小野, 允寛"}, {"creatorName": "オノ, ヨシヒロ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "1063", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "櫻井, 将洋"}, {"creatorName": "サクライ, マサヒロ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "1064", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮内, 勇弥"}, {"creatorName": "ミヤウチ, ユウヤ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "1065", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大高, 泰靖"}, {"creatorName": "オオタカ, ヒロヤス", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "784", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "9000259289864", "nameIdentifierScheme": "CiNii ID", "nameIdentifierURI": "http://ci.nii.ac.jp/nrid/9000259289864"}]}, {"creatorNames": [{"creatorName": "澁川, 明正"}, {"creatorName": "シブカワ, アキマサ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "785", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "9000259289867", "nameIdentifierScheme": "CiNii ID", "nameIdentifierURI": "http://ci.nii.ac.jp/nrid/9000259289867"}]}, {"creatorNames": [{"creatorName": "SUGIMOTO, Kanji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "786", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ONO, Yoshihiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1066", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SAKURAI, Masahiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1067", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MIYAUCHI, Yuuya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1068", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OHTAKA, Hiroyasu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "680", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SHIBUKAWA, Akimasa", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "683", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2021-04-08"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "64-69杉本幹治先生.pdf", "filesize": [{"value": "884.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "copyright (c) 2020 by Chiba Institute of Science", "licensetype": "license_free", "mimetype": "application/pdf", "size": 884200.0, "url": {"label": "64-69杉本幹治", "url": "https://cis.repo.nii.ac.jp/record/348/files/64-69杉本幹治先生.pdf"}, "version_id": "3b043842-c9a2-4f13-b7d5-a5814cd38650"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "高性能先端分析法(High-performance Frontal Analysis)を用いた薬物−血漿タンパク結合解析における試料中血漿タンパク濃度の影響", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "高性能先端分析法(High-performance Frontal Analysis)を用いた薬物−血漿タンパク結合解析における試料中血漿タンパク濃度の影響"}, {"subitem_title": "Effect of plasma protein concentration in sample solutions on drug-plasma protein binding analysis by using High-performance Frontal Analysis.", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "15", "path": ["31"], "permalink_uri": "https://cis.repo.nii.ac.jp/records/348", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-04-08"}, "publish_date": "2021-04-08", "publish_status": "0", "recid": "348", "relation": {}, "relation_version_is_last": true, "title": ["高性能先端分析法(High-performance Frontal Analysis)を用いた薬物−血漿タンパク結合解析における試料中血漿タンパク濃度の影響"], "weko_shared_id": -1}
高性能先端分析法(High-performance Frontal Analysis)を用いた薬物−血漿タンパク結合解析における試料中血漿タンパク濃度の影響
https://cis.repo.nii.ac.jp/records/348
https://cis.repo.nii.ac.jp/records/348789b713d-544d-4dbf-9564-5c1817618ac2
名前 / ファイル | ライセンス | アクション |
---|---|---|
64-69杉本幹治 (884.2 kB)
|
copyright (c) 2020 by Chiba Institute of Science
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-04-08 | |||||
タイトル | ||||||
タイトル | 高性能先端分析法(High-performance Frontal Analysis)を用いた薬物−血漿タンパク結合解析における試料中血漿タンパク濃度の影響 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Effect of plasma protein concentration in sample solutions on drug-plasma protein binding analysis by using High-performance Frontal Analysis. | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
杉本, 幹治
× 杉本, 幹治× 小野, 允寛× 櫻井, 将洋× 宮内, 勇弥× 大高, 泰靖× 澁川, 明正× SUGIMOTO, Kanji× ONO, Yoshihiro× SAKURAI, Masahiro× MIYAUCHI, Yuuya× OHTAKA, Hiroyasu× SHIBUKAWA, Akimasa |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 高性能先端分析( High-performance Frontal Analysis, HPFA)法は HPLCシステムを利用する薬物 血漿タンパク結合分析法であり、オンラインで簡便、高感度な結合分析が可能となる。これまでの検討では、血中モデルタンパク質としてヒト血清アルブミン( HSA)を採用し、本法にて様々な薬物との解析を試みてきた。HSAは 分子量約66500の主要な血漿タンパク質であり、通常35~50g/L≒ 500~750μMの濃度で血漿中に存在しているが、モデル試料においてはHPFA解析モデルの立証と再現性のみに注視し、100μMの濃度で固定して測定を行ってきた。そこで本研究では、試料中HSA総濃度を 変更したときに、薬物-血漿タンパク結合解析から得られる結合定数に変化が見られるかを検討した。オンラインHPFAシステムを構築し、HPFA分離カラムにDevelosil 100Diol-5(6.0 mmI.D.×150mm, Nomura Chemical Co.,Ltd)、薬物定量カラムに5C18-MS-II(2.0mmI.D.×150mm,nacalai tesque,Inc.)を使用、モデル薬物にはphenylbutazone(PB)を 採用し、100、50、10μMのHSA総濃度に対し複数のPB濃度で混合した試料を作成して、カラム温度37℃の条件で測定した。得られた非結合型薬物濃度からLangmuir型のプロットより回帰計算(Kaleida Graph™ ver.4.5, Synergy Software)を行い、結合定数を算出した。HSA総濃度を変化させてもLangmuir型プロットは同一のものとなり、算出した結合定数、及び結合サイト数も同一の値となった。本検討結果より、HPFA解析においてHSA濃度を変化させても影響はなく、薬物 -血漿タンパク結合における評価の妥当性があることが示された。 | |||||
書誌情報 |
千葉科学大学紀紀要 en : The University Bulletin of Chiba Insitute of Science 号 14, p. 64-69, 発行日 2021-03-28 |
|||||
出版者 | ||||||
出版者 | 千葉科学大学 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2436-2565 | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |